FirePreplans

Goldsboro, North Carolina. Wayne County.

Grantham Volunteer Fire Department

  • 2,195pre-plans, about one per building
  • 2life-risk sites
  • 206estimated to need over 1,000 gpm
  • 12in the flood zone

Estimated from public records. Your officers fix what is off in setup.

See a sample pre-plan

All volunteer department. 1 station. 38 volunteer firefighters.

Grantham Elementary, public schoolGrantham Middle, public schoolGrantham Volunteer Fire Department - Wayne County Station 19Grantham Elem.Grantham MiddleSTATION 192 miNGrantham Elementary, public schoolGrantham Middle, public schoolGrantham Volunteer Fire Department - Wayne County Station 19Grantham Elem.Grantham MiddleSTATION 192 miN
  • Your first due
  • Stations
  • Life-risk sites
Your first due from your county's published response areas, as of Jul 2025.

Your first due by the numbers.

2,195pre-plans to draft, estimated: about one for every building in your first dueEstimatedBuilding records as of Jun 2025
2life-risk sites: nursing homes, schools, hospitals, care homes and day caresEstimated
206buildings that need more than 1,000 gpmEstimated
12buildings in the 100-year flood zone, mapped zones onlyEstimatedFlood maps as of Oct 2026
At setuphydrants. Send your hydrant list or map in any form, or mark them in setup, and every card plans its water from them.
31square miles of first duePublished by your countyAs of Jul 2025

About 4,148 people live in these buildings, estimated from the building records.

How to read these numbers. Estimated means we worked it out from public records, and your officers check it at setup. The month is when its list was last updated. A check flag means the list is more than 2 years old, so look at it first.

Numbers built October 2026. Your officers fix anything that is off in setup, and every card follows.

Buildings by type

  • Homes1,405
  • Mobile homes659
  • Industrial39
  • Sheds, utility and other30
  • Businesses24
  • Schools22
  • Government and assembly13
  • Apartments and lodging3
EstimatedBuilding records as of Jun 2025

Water need, in gpm

  • 250 or less1,257
  • 300 to 500487
  • 550 to 1,000245
  • 1,050 to 2,000119
  • over 2,00087
Estimated

Water need by the NFA formula, with 25% of the building involved. Homes and apartment buildings with no recorded height are counted as 2 floors; your officers can set heights in setup.

Shuttle loop times and rig counts are worked out card by card, from your tankers or tenders, your fill sites and your roads, once your officers enter them in setup.

Life-risk sites

Nursing homes, hospitals, care homes, schools and day cares that are first due to you, from state and national lists. Each list carries its own date.

NameTypeSizeList as of
Grantham ElementaryPublic school442 studentsJun 2025
Grantham MiddlePublic school301 studentsJun 2025

Your stations.

Each card routes from the station that is first due, so the way in matches how your rigs come. Add or fix stations in setup.

  • Grantham Volunteer Fire Department - Wayne County Station 19Record dated Dec 2019