FirePreplans

Notre Dame, Indiana. St Joseph County.

University of Notre Dame Fire Department

  • 315pre-plans, about one per building
  • 3life-risk sites
  • 135estimated to need over 1,000 gpm
  • 0in the flood zone

Estimated from public records. Your officers fix what is off in setup.

See a sample pre-plan

Mostly volunteer department. 1 station. 16 career firefighters.

Wellbrooke Of South Bend, nursing homeHoly Cross Village At Notre Dame Inc, nursing homeEarly Childhood Develop Center, private schoolUniversity of Notre Dame Fire DepartmentWellbrookeHoly Cross VillageEarly ChildhoodSTATION0.5 miNWellbrooke Of South Bend, nursing homeHoly Cross Village At Notre Dame Inc, nursing homeEarly Childhood Develop Center, private schoolUniversity of Notre Dame Fire DepartmentWellbrookeHoly Cross VillageEarly ChildhoodSTATION1 miN
  • Your first due
  • Stations
  • Life-risk sites
Your first due from your county's published response areas, as of Jul 2026.

Your first due by the numbers.

315pre-plans to draft, estimated: about one for every building in your first dueEstimatedBuilding records as of Sep 2025
3life-risk sites: nursing homes, schools, hospitals, care homes and day caresEstimatedCheck: list over 2 years old
135buildings that need more than 1,000 gpmEstimated
0buildings in the 100-year flood zone, mapped zones onlyEstimatedFlood maps as of Oct 2026
33hydrants mapped, covering about 63% of your buildingsHydrant maps as of Feb 2025
3square miles of first duePublished by your countyAs of Jul 2026

About 519 people live in these buildings, estimated from the building records.

How to read these numbers. Estimated means we worked it out from public records, and your officers check it at setup. The month is when its list was last updated. A check flag means the list is more than 2 years old, so look at it first.

Numbers built October 2026. Your officers fix anything that is off in setup, and every card follows.

Buildings by type

  • Schools273
  • Homes30
  • Apartments and lodging7
  • Government and assembly3
  • Nursing homes and hospitals1
  • Sheds, utility and other1
EstimatedBuilding records as of Sep 2025

Water need, in gpm

  • 250 or less66
  • 300 to 50052
  • 550 to 1,00062
  • 1,050 to 2,00057
  • over 2,00078
Estimated

Water need by the NFA formula, with 25% of the building involved. Homes and apartment buildings with no recorded height are counted as 2 floors; your officers can set heights in setup.

Shuttle loop times and rig counts are worked out card by card, from your tankers or tenders, your fill sites and your roads, once your officers enter them in setup.

Life-risk sites

Nursing homes, hospitals, care homes, schools and day cares that are first due to you, from state and national lists. Each list carries its own date.

NameTypeSizeList as of
Wellbrooke Of South BendNursing home70 bedsSep 2026
Holy Cross Village At Notre Dame IncNursing home52 bedsSep 2026
Early Childhood Develop CenterPrivate school24 studentsJun 2024 Check

Your stations.

Each card routes from the station that is first due, so the way in matches how your rigs come. Add or fix stations in setup.

  • University of Notre Dame Fire DepartmentRecord dated Mar 2015